EEG dataset for 64 channels
This dataset was created and contributed to PhysioNet by the developers of the BCI2000 instrumentation system, which they used in making these recordings. Subjects performed different motor/imagery tasks while 64-channel EEG was recorded using the BCI2000 system. Each subject performed 14 experimental runs: two one-minute baseline runs (one with eyes open, one with eyes closed), and three two-minute runs of each of the four following tasks:
1. A target appears on either the left or the right side of the screen. The subject opens and closes the corresponding fist until the target disappears. Then the subject relaxes.
2. A target appears on either the left or the right side of the screen. The subject imagines opening and closing the corresponding fist until the target disappears. Then the subject relaxes.
3. A target appears on either the top or the bottom of the screen. The subject opens and closes either fists (if the target is on top) or both feet (if the target is on the bottom) until the target disappears. Then the subject relaxes.
4. A target appears on either the top or the bottom of the screen. The subject imagines opening and closing either both fists (if the target is on top) or both feet (if the target is on the bottom) until the target disappears. Then the subject relaxes.
In summary, the experimental runs were:
1. Baseline, eyes open
2. Baseline, eyes closed
3. Task 1 (open and close left or right fist)
4. Task 2 (imagine opening and closing left or right fist)
The data are provided here in EDF+ format (containing 64 EEG signals, each sampled at 160 samples per second, and an annotation channel). For use with PhysioToolkit software, generated a separate PhysioBank-compatible annotation file (with the suffix .event) for each recording. The .event files and the annotation channels in the corresponding .edf files contain identical data.
The EEGs were recorded from 64 electrodes as per the international 10-10 system (excluding electrodes Nz, F9, F10, FT9, FT10, A1, A2, TP9, TP10, P9, and P10), as shown figure 10. The numbers below each electrode name indicate the order in which they appear in the records; note that signals in the records are numbered from 0 to 63, while the numbers in the figure range from 1 to 64. [1]

Figure 1 Montage for 64 channel using International 10-10 system [1]
References:
[1] http://biosig.sourceforge.net/
1. A target appears on either the left or the right side of the screen. The subject opens and closes the corresponding fist until the target disappears. Then the subject relaxes.
2. A target appears on either the left or the right side of the screen. The subject imagines opening and closing the corresponding fist until the target disappears. Then the subject relaxes.
3. A target appears on either the top or the bottom of the screen. The subject opens and closes either fists (if the target is on top) or both feet (if the target is on the bottom) until the target disappears. Then the subject relaxes.
4. A target appears on either the top or the bottom of the screen. The subject imagines opening and closing either both fists (if the target is on top) or both feet (if the target is on the bottom) until the target disappears. Then the subject relaxes.
In summary, the experimental runs were:
1. Baseline, eyes open
2. Baseline, eyes closed
3. Task 1 (open and close left or right fist)
4. Task 2 (imagine opening and closing left or right fist)
The data are provided here in EDF+ format (containing 64 EEG signals, each sampled at 160 samples per second, and an annotation channel). For use with PhysioToolkit software, generated a separate PhysioBank-compatible annotation file (with the suffix .event) for each recording. The .event files and the annotation channels in the corresponding .edf files contain identical data.
The EEGs were recorded from 64 electrodes as per the international 10-10 system (excluding electrodes Nz, F9, F10, FT9, FT10, A1, A2, TP9, TP10, P9, and P10), as shown figure 10. The numbers below each electrode name indicate the order in which they appear in the records; note that signals in the records are numbered from 0 to 63, while the numbers in the figure range from 1 to 64. [1]
Figure 1 Montage for 64 channel using International 10-10 system [1]
References:
[1] http://biosig.sourceforge.net/